STRE SGLB Misc/Class Reference CLAS 355062 /:6 ESBR SORD 2 PORD 0 7203/:s,-30000,30000,1.0;%.0f rpm;(1203) TOTAL SPD DEMAND RPM PORD 0 7206/:s,-30000,30000,0.01;%.2f %%;(1206) TOTAL SPD DEMAND % PORD 0 7207/:s,-30000,30000,0.01;%.2f %%;(1207) SPEED ERROR PORD 0 7204/:s,-30000,30000,0.01;%.2f %%;(1204) TORQUE DEMAND PORD 0 7205/:s,-30000,30000,0.01;%.2f %%;(1205) DIRECT INPUT PORD 200 7187/s,0,30000,0.01;%.2f;(1187) SPEED PROP GAIN PORD 100 7188/s,1,15000,1.0;%.0f ms;(1188) SPEED INT TIME PORD 0 7189/t,False,True;(1189) INT DEFEAT PORD 0 7190/s,-5000,5000,0.1;%.1f %%;(1190) SPEED INT PRESET PORD 30 7191/s,0,140,0.1;%.1f ms;(1191) SPEED DMD FILTER PORD 15 7192/s,0,150,0.1;%.1f ms;(1192) SPEED FBK FILTER PORD 0 7193/s,-20000,20000,0.01;%.2f %%;(1193) AUX TORQUE DMD PORD 0 7194/s,0,10000,0.001;%.3f %%;(1194) ADAPTIVE THRESH PORD 0 7195/s,0,10000,0.1;%.1f;(1195) ADAPTIVE P-GAIN PORD 0 7196/ev,NONE,ANIN 1,ANIN 2,ANIN 3,ANIN 4;(1196) DIRECT IP SELECT PORD 1000 7197/s,-10000,10000,0.001;%.3f;(1197) DIRECT RATIO PORD 10000 7198/s,-11000,11000,0.01;%.2f %%;(1198) DIRECT IP POS LIM PORD 55536 7199/s,-11000,11000,0.01;%.2f %%;(1199) DIRECT IP NEG LIM PORD 10000 7200/s,-11000,11000,0.01;%.2f %%;(1200) SPEED POS LIM PORD 55536 7201/s,-11000,11000,0.01;%.2f %%;(1201) SPEED NEG LIM PORD 0 7202/t,False,True;(1202) TORQ DMD ISOLATE ESBR SORD 7203 LCON /*p|0,0,0,0,TOTAL SPD DEMAND RPM;(1203) TOTAL SPD DEMAND RPM ESBR SORD 7206 LCON /*p|0,0,0,0,TOTAL SPD DEMAND %;(1206) TOTAL SPD DEMAND % ESBR SORD 7207 LCON /*p|0,0,0,0,SPEED ERROR;(1207) SPEED ERROR ESBR SORD 7204 LCON /*p|0,0,0,0,TORQUE DEMAND;(1204) TORQUE DEMAND ESBR SORD 7205 LCON /*p|0,0,0,0,DIRECT INPUT;(1205) DIRECT INPUT ESBR SORD 7187 LCON /*p|0,0,0,0, ;(1187) SPEED PROP GAIN ESBR SORD 7188 LCON /*p|0,0,0,0, ;(1188) SPEED INT TIME ESBR SORD 7189 LCON /*p|0,0,0,0, ;(1189) INT DEFEAT ESBR SORD 7190 LCON /*p|0,0,0,0, ;(1190) SPEED INT PRESET ESBR SORD 7191 LCON /*p|0,0,0,0, ;(1191) SPEED DMD FILTER ESBR SORD 7192 LCON /*p|0,0,0,0, ;(1192) SPEED FBK FILTER ESBR SORD 7193 LCON /*p|0,0,0,0, ;(1193) AUX TORQUE DMD ESBR SORD 7194 LCON /*p|0,0,0,0, ;(1194) ADAPTIVE THRESH ESBR SORD 7195 LCON /*p|0,0,0,0, ;(1195) ADAPTIVE P-GAIN ESBR SORD 7196 LCON /*p|0,0,0,0, ;(1196) DIRECT IP SELECT ESBR SORD 7197 LCON /*p|0,0,0,0, ;(1197) DIRECT RATIO ESBR SORD 7198 LCON /*p|0,0,0,0, ;(1198) DIRECT IP POS LIM ESBR SORD 7199 LCON /*p|0,0,0,0, ;(1199) DIRECT IP NEG LIM ESBR SORD 7200 LCON /*p|0,0,0,0, ;(1200) SPEED POS LIM ESBR SORD 7201 LCON /*p|0,0,0,0, ;(1201) SPEED NEG LIM ESBR SORD 7202 LCON /*p|0,0,0,0, ;(1202) TORQ DMD ISOLATE ESBR ESTR STRE SGLB Misc/Superclass Reference CLAS 354008 Object ESBR SGLB Drive/SPEED PROP GAIN /3s,0,30000,0.01;Enter SPEED PROP GAIN... LITO 6 ESBR SGLB Drive/SPEED INT TIME /3s,1,15000,1.0;Enter SPEED INT TIME... LITO 7 ESBR SGLB Drive/INT DEFEAT /3t,False,True;Select INT DEFEAT... LITO 8 ESBR SGLB Drive/SPEED INT PRESET /3s,-5000,5000,0.1;Enter SPEED INT PRESET... LITO 9 ESBR SGLB Drive/SPEED DMD FILTER /3s,0,140,0.1;Enter SPEED DMD FILTER... LITO 10 ESBR SGLB Drive/SPEED FBK FILTER /3s,0,150,0.1;Enter SPEED FBK FILTER... LITO 11 ESBR SGLB Drive/AUX TORQUE DMD /3s,-20000,20000,0.01;Enter AUX TORQUE DMD... LITO 12 ESBR SGLB Drive/ADAPTIVE THRESH /3s,0,10000,0.001;Enter ADAPTIVE THRESH... LITO 13 ESBR SGLB Drive/ADAPTIVE P-GAIN /3s,0,10000,0.1;Enter ADAPTIVE P-GAIN... LITO 14 ESBR SGLB Drive/DIRECT IP SELECT /3e,NONE,ANIN 1,ANIN 2,ANIN 3,ANIN 4;Select DIRECT IP SELECT... LITO 15 ESBR SGLB Drive/DIRECT RATIO /3s,-10000,10000,0.001;Enter DIRECT RATIO... LITO 16 ESBR SGLB Drive/DIRECT IP POS LIM /3s,-11000,11000,0.01;Enter DIRECT IP POS LIM... LITO 17 ESBR SGLB Drive/DIRECT IP NEG LIM /3s,-11000,11000,0.01;Enter DIRECT IP NEG LIM... LITO 18 ESBR SGLB Drive/SPEED POS LIM /3s,-11000,11000,0.01;Enter SPEED POS LIM... LITO 19 ESBR SGLB Drive/SPEED NEG LIM /3s,-11000,11000,0.01;Enter SPEED NEG LIM... LITO 20 ESBR SGLB Drive/TORQ DMD ISOLATE /3t,False,True;Select TORQ DMD ISOLATE... LITO 21 ESBR SGLB Drive/Get TOTAL SPD DEMAND RPM /2s,-30000,30000,1.0;%.0f rpm LITO 1 ESBR SGLB Drive/Get TOTAL SPD DEMAND % /2s,-30000,30000,0.01;%.2f %% LITO 2 ESBR SGLB Drive/Get SPEED ERROR /2s,-30000,30000,0.01;%.2f %% LITO 3 ESBR SGLB Drive/Get TORQUE DEMAND /2s,-30000,30000,0.01;%.2f %% LITO 4 ESBR SGLB Drive/Get DIRECT INPUT /2s,-30000,30000,0.01;%.2f %% LITO 5 ESBR SGLB Drive/Get SPEED PROP GAIN /2s,0,30000,0.01;%.2f LITO 6 ESBR SGLB Drive/Get SPEED INT TIME /2s,1,15000,1.0;%.0f ms LITO 7 ESBR SGLB Drive/Get INT DEFEAT /2t,False,True LITO 8 ESBR SGLB Drive/Get SPEED INT PRESET /2s,-5000,5000,0.1;%.1f %% LITO 9 ESBR SGLB Drive/Get SPEED DMD FILTER /2s,0,140,0.1;%.1f ms LITO 10 ESBR SGLB Drive/Get SPEED FBK FILTER /2s,0,150,0.1;%.1f ms LITO 11 ESBR SGLB Drive/Get AUX TORQUE DMD /2s,-20000,20000,0.01;%.2f %% LITO 12 ESBR SGLB Drive/Get ADAPTIVE THRESH /2s,0,10000,0.001;%.4f %% LITO 13 ESBR SGLB Drive/Get ADAPTIVE P-GAIN /2s,0,10000,0.1;%.1f LITO 14 ESBR SGLB Drive/Get DIRECT IP SELECT /2e,NONE,ANIN 1,ANIN 2,ANIN 3,ANIN 4 LITO 15 ESBR SGLB Drive/Get DIRECT RATIO /2s,-10000,10000,0.001;%.3f LITO 16 ESBR SGLB Drive/Get DIRECT IP POS LIM /2s,-11000,11000,0.01;%.2f %% LITO 17 ESBR SGLB Drive/Get DIRECT IP NEG LIM /2s,-11000,11000,0.01;%.2f %% LITO 18 ESBR SGLB Drive/Get SPEED POS LIM /2s,-11000,11000,0.01;%.2f %% LITO 19 ESBR SGLB Drive/Get SPEED NEG LIM /2s,-11000,11000,0.01;%.2f %% LITO 20 ESBR SGLB Drive/Get TORQ DMD ISOLATE /2t,False,True LITO 21 ESBR ESTR CMTL 5 graphic info CMNT 4 -18,-18,818,1598 CMTL 3 0 CMNT 24 20,0,432,45,2,6,SPEED PROP GAIN;Drive/SPEED PROP GAIN CMNT 24 20,0,504,45,2,7,SPEED INT TIME;Drive/SPEED INT TIME CMNT 24 20,0,576,45,2,8,INT DEFEAT;Drive/INT DEFEAT CMNT 24 20,0,648,45,2,9,SPEED INT PRESET;Drive/SPEED INT PRESET CMNT 24 20,0,720,45,2,10,SPEED DMD FILTER;Drive/SPEED DMD FILTER CMNT 24 20,0,792,45,2,11,SPEED FBK FILTER;Drive/SPEED FBK FILTER CMNT 24 20,0,864,45,2,12,AUX TORQUE DMD;Drive/AUX TORQUE DMD CMNT 24 20,0,936,45,2,13,ADAPTIVE THRESH;Drive/ADAPTIVE THRESH CMNT 24 20,0,1008,45,2,14,ADAPTIVE P-GAIN;Drive/ADAPTIVE P-GAIN CMNT 24 20,0,1080,45,2,15,DIRECT IP SELECT;Drive/DIRECT IP SELECT CMNT 24 20,0,1152,45,2,16,DIRECT RATIO;Drive/DIRECT RATIO CMNT 24 20,0,1224,45,2,17,DIRECT IP POS LIM;Drive/DIRECT IP POS LIM CMNT 24 20,0,1296,45,2,18,DIRECT IP NEG LIM;Drive/DIRECT IP NEG LIM CMNT 24 20,0,1368,45,2,19,SPEED POS LIM;Drive/SPEED POS LIM CMNT 24 20,0,1440,45,2,20,SPEED NEG LIM;Drive/SPEED NEG LIM CMNT 24 20,0,1512,45,2,21,TORQ DMD ISOLATE;Drive/TORQ DMD ISOLATE ECMT CMTL 7 0 CMNT 14 810,68,1,2,1,Drive/Get TOTAL SPD DEMAND RPM;/w,-30000,30000,1.0;%.0f rpm CMNT 14 810,140,1,2,2,Drive/Get TOTAL SPD DEMAND %;/w,-30000,30000,0.01;%.2f %% CMNT 14 810,212,1,2,3,Drive/Get SPEED ERROR;/w,-30000,30000,0.01;%.2f %% CMNT 14 810,284,1,2,4,Drive/Get TORQUE DEMAND;/w,-30000,30000,0.01;%.2f %% CMNT 14 810,356,1,2,5,Drive/Get DIRECT INPUT;/w,-30000,30000,0.01;%.2f %% CMNT 22 -10,428,0,2,6,Drive/Get SPEED PROP GAIN;/w,0,30000,0.01;%.2f CMNT 22 -10,500,0,2,7,Drive/Get SPEED INT TIME;/w,1,15000,1.0;%.0f ms CMNT 22 -10,572,0,2,8,Drive/Get INT DEFEAT;/t,FALSE,TRUE CMNT 22 -10,644,0,2,9,Drive/Get SPEED INT PRESET;/w,-5000,5000,0.1;%.1f %% CMNT 22 -10,716,0,2,10,Drive/Get SPEED DMD FILTER;/w,0,140,0.1;%.1f ms CMNT 22 -10,788,0,2,11,Drive/Get SPEED FBK FILTER;/w,0,150,0.1;%.1f ms CMNT 22 -10,860,0,2,12,Drive/Get AUX TORQUE DMD;/w,-20000,20000,0.01;%.2f %% CMNT 22 -10,932,0,2,13,Drive/Get ADAPTIVE THRESH;/w,0,10000,0.001;%.3f %% CMNT 22 -10,1004,0,2,14,Drive/Get ADAPTIVE P-GAIN;/w,0,10000,0.1;%.1f CMNT 22 -10,1076,0,2,15,Drive/Get DIRECT IP SELECT;/e,NONE,ANIN 1,ANIN 2,ANIN 3,ANIN 4 CMNT 22 -10,1148,0,2,16,Drive/Get DIRECT RATIO;/w,-10000,10000,0.001;%.3f CMNT 22 -10,1220,0,2,17,Drive/Get DIRECT IP POS LIM;/w,-11000,11000,0.01;%.2f %% CMNT 22 -10,1292,0,2,18,Drive/Get DIRECT IP NEG LIM;/w,-11000,11000,0.01;%.2f %% CMNT 22 -10,1364,0,2,19,Drive/Get SPEED POS LIM;/w,-11000,11000,0.01;%.2f %% CMNT 22 -10,1436,0,2,20,Drive/Get SPEED NEG LIM;/w,-11000,11000,0.01;%.2f %% CMNT 22 -10,1508,0,2,21,Drive/Get TORQ DMD ISOLATE;/t,FALSE,TRUE ECMT CMNT 8 0,0,800,1580 ECMT