STRE Prototype SGLB Misc/Class Reference CLAS 354546 ESBR SORD 2 /e,,,Ramp Data;Parameters PORD 100 17/s,0,6000,0.1;%.1f seconds;Ramp Accel Time PORD 100 18/s,0,6000,0.1;%.1f seconds;Ramp Decel Time PORD 1 19/t,Disabled,Enabled;Constant Accel PORD 0 133/e,Ramp,Hold;Ramp Enable PORD 0 141/s,0,10000,0.01;%.2f%%;Ramp Min Speed PORD 500 281/s,0,10000,0.01;%.2f%%;Ramp S % PORD 50 301/s,0,10000,0.01;%.2f%%;Ramp Finished Threshold PORD 1 302/e,Disabled,Enabled;Ramp Auto Reset PORD 0 303/e,Disabled,Enabled;Ramp Ext Reset PORD 0 318/e,Disabled,Enabled;Ramp Speed Fbk Reset ESBR SORD 3 /e,,,,Reserved;Authorized Use Only PORD 291 308/o;Ramp Output Dest Tag PORD 0 20/:Ramp input ESBR SGLB Drive/Get Ramp Input LCON /*d;Ramp Input ESBR SGLB Drive/Get Ramp Output LCON /*d|0,0,144,45,RAMP OUTPUT;Ramp Output ESBR SGLB Drive/Get Ramp Accel Time LCON /*d;Ramp Accel Time ESBR SGLB Drive/Get Ramp Decel Time LCON /*d;Ramp Decel Time ESBR SGLB Drive/Get Constant Accel LCON /*d;Constant Accel ESBR SGLB Drive/Get Ramp Hold LCON /*d;Ramp Hold ESBR SGLB Drive/Get Ramp Min Speed LCON /*d;Ramp Min Speed ESBR SGLB Drive/Get Ramp S % LCON /*d;Ramp S % ESBR SGLB Drive/Get Ramp Finished Thresh LCON /*d;Ramp Finished Thresh ESBR SGLB Drive/Get Ramp Auto Reset LCON /*d;Ramp Auto Reset ESBR SGLB Drive/Get Ramp Ext Reset LCON /*d;Ramp Ext Reset ESBR SGLB Drive/Get Ramp Spd Fbk Reset LCON /*d;Ramp Spd Fbk Reset ESBR SGLB Drive/Get Ramping LCON /*d;Ramping ESBR ESTR STRE SGLB Misc/Superclass Reference CSYM 354546 ESBR SGLB Drive/Ramp Input /3v107,-120,120,-105,105;Enter Ramp Input (%) ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp Input /2v58,-120,120;%3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp Output /2v58,-120,120;%3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Ramp Accel Time /3v130,-600,600,0.1,600;Enter Ramp Accel Time ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp Accel Time /2v131,-600,600;%3.1f Seconds ASIO Drive/ERROR ESBR SGLB Drive/Ramp Decel Time /3v130,-600,600,0.1,600;Enter Ramp Decel Time ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp Decel Time /2v131,-600,600;%3.1f Seconds ASIO Drive/ERROR ESBR SGLB Drive/Constant Accel /3t12,Disabled,Enabled;Constant Accel ASIO Drive/ERROR ESBR SGLB Drive/Get Constant Accel /2t11,Disabled,Enabled ASIO Drive/ERROR ESBR SGLB Drive/Ramp Hold /3t60,Ramp,Hold;Ramp Hold ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp Hold /2t61,Ramp,Hold ASIO Drive/ERROR ESBR SGLB Drive/Ramp Min Speed /3v138,-120,120,0,100;Enter Ramp Min Speed (%) ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp Min Speed /2v58,-120,120;%3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Ramp S % /3v138,-120,120,0,100;Enter Ramp S % ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp S % /2v58,-120,120;%3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Ramp Finished Thresh /3v138,-120,120,0,100;Enter Ramp Finished Thresh (%) ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp Finished Thresh /2v58,-120,120;%3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Ramp Auto Reset /3t12,Disabled,Enabled;Ramp Ext Reset Ena ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp Auto Reset /2t11,Disabled,Enabled ASIO Drive/ERROR ESBR SGLB Drive/Ramp Ext Reset /3t12,Disabled,Enabled;Ramp Ext Reset ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp Ext Reset /2t11,Disabled,Enabled ASIO Drive/ERROR ESBR SGLB Drive/Ramp Spd Fbk Reset /3t12,Disabled,Enabled;Ramp Spd Fbk Reset ASIO Drive/ERROR ESBR SGLB Drive/Get Ramp Spd Fbk Reset /2t11,Disabled,Enabled ASIO Drive/ERROR ESBR SGLB Drive/Get Ramping /2t4,False,True ASIO Drive/ERROR ESBR ESTR CMTL 5 graphic info CMNT 4 -18,-18,1800,1260 CMTL 3 0 CMNT 24 20,0,72,45,3,2,RAMP INPUT;Drive/Ramp Input CMNT 24 20,0,144,45,2,1,RAMP ACCEL TIME;Drive/Ramp Accel Time CMNT 24 20,0,216,45,2,2,RAMP DECEL TIME;Drive/Ramp Decel Time CMNT 24 20,0,288,45,2,3,CONSTANT ACCEL;Drive/Constant Accel CMNT 24 20,0,360,45,2,4,RAMP HOLD;Drive/Ramp Hold CMNT 24 20,0,432,45,2,5,RAMP MIN SPEED;Drive/Ramp Min Speed CMNT 24 20,0,504,45,2,6,RAMP S %;Drive/Ramp S % CMNT 24 20,0,576,45,2,7,RAMP FINISHED THRESH;Drive/Ramp Finished Thresh CMNT 24 20,0,648,45,2,8,RAMP AUTO RESET;Drive/Ramp Auto Reset CMNT 24 20,0,720,45,2,9,RAMP EXT RESET;Drive/Ramp Ext Reset CMNT 24 20,0,792,45,2,10,SPD FBK RESET;Drive/Ramp Spd Fbk Reset ECMT CMTL 7 0 CMNT 22 -10,68,0,3,2,Drive/Get Ramp Input;/w,-12000,12000,0.01,%.2f%% CMNT 22 -10,140,0,2,1,Drive/Get Ramp Accel Time;/w,-6000,6000,0.1,%.1fs CMNT 22 -10,212,0,2,2,Drive/Get Ramp Decel Time;/w,-6000,6000,0.1,%.1fs CMNT 22 -10,284,0,2,3,Drive/Get Constant Accel;/t,Disabled,Enabled CMNT 22 -10,356,0,2,4,Drive/Get Ramp Hold;/t,Ramp,Hold CMNT 22 -10,428,0,2,5,Drive/Get Ramp Min Speed;/w,0,12000,0.01,%.2f%% CMNT 22 -10,500,0,2,6,Drive/Get Ramp S %;/w,0,12000,0.01,%.2f%% CMNT 22 -10,572,0,2,7,Drive/Get Ramp Finished Thresh;/w,0,12000,0.01,%.2f%% CMNT 22 -10,644,0,2,8,Drive/Get Ramp Auto Reset;/t,Disabled,Enabled CMNT 22 -10,716,0,2,9,Drive/Get Ramp Ext Reset;/t,Disabled,Enabled CMNT 22 -10,788,0,2,10,Drive/Get Ramp Spd Fbk Reset;/t,Disabled,Enabled CMNT 14 1792,140,1,0,1,Drive/Get Ramp Output;/w,-12000,12000,0.01,%.2f%% CMNT 14 1792,932,1,0,2,Drive/Get Ramping;/t,False,True ECMT CMNT 8 0,0,1782,1242 CMNT 12 675,1152,675,882 CMNT 12 630,1107,1170,1107 CMNT 12 675,1107,765,1017 CMNT 10 835,1017 CMNT 10 925,927 CMNT 10 975,927 CMNT 10 1100,1107 ECMT