STRE Prototype SGLB Misc/Class Reference CLAS 354447 ESBR SORD 2 /e,,,Field;Parameters PORD 1 185/e,Disable,Enable;Field Enable PORD 0 224/e,Voltage Control,Current Control;Field Control Mode PORD 10000 197/s,9800,11000,0.0001;%.4f;Field I Cal PORD 0 200/s,0,6000,0.1;%.1f seconds;Field Quench Delay PORD 0 201/e,Quench,Standby;Field Quench Mode ESBR SORD 3 /e,,,,Current Control;Parameters PORD 10000 186/s,0,10000,0.01;%.2f%%;Field Setpoint PORD 128 187/s,0,10000,0.01;%.2f;Field Loop I Gain PORD 10 188/s,0,10000,0.01;%.2f;Field Loop P Gain ESBR SORD 4 /e,,,,,Field Weakening;Parameters PORD 0 189/e,Disable,Enable;Field Weakening PORD 200 190/s,10,5000,0.01;%.2f;EMF Lead Time Const PORD 4000 191/s,0,20000,0.01;%.2f;EMF Lag Time Const PORD 30 192/s,0,10000,0.01;%.2f;EMF Gain PORD 10000 193/s,0,10000,0.01;%.2f%%;Max Armature Volts PORD 1000 194/s,0,10000,0.01;%.2f%%;Field Weakening Limit PORD 100 206/s,10,5000,1;%.0f;BEMF Feedback Lead PORD 100 207/s,10,5000,1;%.0f;BEMF Feedback Lag ESBR SORD 5 /e,,,,,,Voltage Control;Parameters PORD 6700 225/s,0,10000,0.01;%.2f%%;Field Voltage Ratio ESBR SORD 6 /e,,,,,,,Reserved;Authorized Use Only PORD 155 49 PORD 209 50 PORD 20 51 PORD 0 184 PORD 0 196 PORD 0 198 PORD 0 199 ESBR SGLB Drive/Get Total Field Setpoint LCON /*d;Total Field Setpoint ESBR SGLB Drive/Get Field Demand LCON /*d;Field Demand ESBR SGLB Drive/Get Field Control Mode LCON /*d;Field Control Mode ESBR SGLB Drive/Get Field Enable LCON /*d;Field Enable ESBR SGLB Drive/Get Field Loop I Gain LCON /*d;Field Loop I Gain ESBR SGLB Drive/Get Field Loop P Gain LCON /*d;Field Loop P Gain ESBR SGLB Drive/Get Field Weakening Enable LCON /*d;Field Weakening Enable ESBR SGLB Drive/Get EMF Lead LCON /*d;EMF Lead ESBR SGLB Drive/Get EMF Lag LCON /*d;EMF Lag ESBR SGLB Drive/Get EMF Gain LCON /*d;EMF Gain ESBR SGLB Drive/Get Max Volts LCON /*d;Max Volts ESBR SGLB Drive/Get Minimum Field Current LCON /*d;Minimum Field Current ESBR SGLB Drive/Get Field Quench Mode LCON /*d;Field Quench Mode ESBR SGLB Drive/Get Field Quench Delay LCON /*d;Field Quench Delay ESBR SGLB Drive/Get Field Ratio Out|In LCON /*d;Field Ratio Out|In ESBR SGLB Drive/Get Cal Field Current LCON /*d;Cal Field Current ESBR SGLB Drive/Get Field Current LCON /*d;Field Current ESBR ESTR STRE SGLB Misc/Superclass Reference CSYM 354447 ESBR SGLB Drive/Get Total Field Setpoint /2v37,-200,200;Total Field Setpoint is %3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Get Field Demand /2v37,-200,200;%3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Field Demand /3v108,-200,200,10,100;Enter Field Demand (10% to 100%)... ASIO Drive/ERROR ESBR SGLB Drive/Field Control Mode /3t46,Voltage,Current;Choose Control Mode ASIO Drive/ERROR ESBR SGLB Drive/Get Field Control Mode /2t47,Voltage Control,Current Control ASIO Drive/ERROR ESBR SGLB Drive/Field Enable /3t12,Disable,Enable;Field Enable ASIO Drive/ERROR ESBR SGLB Drive/Get Field Enable /2t11,Disabled,Enabled ASIO Drive/ERROR ESBR SGLB Drive/Field Loop I Gain /3v10,-100,100,0,100;Enter Field Loop I Gain ASIO Drive/ERROR ESBR SGLB Drive/Get Field Loop I Gain /2v9,-100,100;%3.2f ASIO Drive/ERROR ESBR SGLB Drive/Field Loop P Gain /3v10,-100,100,0,100;Enter Field Loop P Gain ASIO Drive/ERROR ESBR SGLB Drive/Get Field Loop P Gain /2v9,-100,100;%3.2f ASIO Drive/ERROR ESBR SGLB Drive/Field Weakening Enable /3t12,Disable,Enable;Field Weakening ASIO Drive/ERROR ESBR SGLB Drive/Get Field Weakening Enable /2t11,Disabled,Enabled ASIO Drive/ERROR ESBR SGLB Drive/EMF Lead /3v43,-50,50,0.1,50;Enter EMF Lead ASIO Drive/ERROR ESBR SGLB Drive/Get EMF Lead /2v93,-50,50;%3.2f ASIO Drive/ERROR ESBR SGLB Drive/EMF Lag /3v120,-200,200,0,200;Enter EMF Lag ASIO Drive/ERROR ESBR SGLB Drive/Get EMF Lag /2v121,-200,200;%3.2f ASIO Drive/ERROR ESBR SGLB Drive/EMF Gain /3v10,-100,100,0,100;Enter EMF Gain ASIO Drive/ERROR ESBR SGLB Drive/Get EMF Gain /2v9,-100,100;%3.2f ASIO Drive/ERROR ESBR SGLB Drive/Max Volts /3v10,-100,100,0,100;Enter Max Armature Voltage ASIO Drive/ERROR ESBR SGLB Drive/Get Max Volts /2v6,-100,100;%3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Minimum Field Current /3v10,-100,100,0,100;Enter Minimum Field Current ASIO Drive/ERROR ESBR SGLB Drive/Get Minimum Field Current /2v6,-100,100;%3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Field Quench Mode /3t49,Quench,Standby;Enter Field Quench Mode ASIO Drive/ERROR ESBR SGLB Drive/Get Field Quench Mode /2t50,Quench,Standby ASIO Drive/ERROR ESBR SGLB Drive/Field Quench Delay /3v130,-600,600,0,600;Enter Field Quench Delay (secs) ASIO Drive/ERROR ESBR SGLB Drive/Get Field Quench Delay /2v131,-600,600;%3.1f s ASIO Drive/ERROR ESBR SGLB Drive/Field Ratio Out|In /3v8,-100,100,0,100;Enter Ratio (%) ASIO Drive/ERROR ESBR SGLB Drive/Get Field Ratio Out|In /2v6,-100,100;%3.0f%% ASIO Drive/ERROR ESBR SGLB Drive/Cal Field Current /3v126,-1.1000,1.1000,.9800,1.1000;Enter Field Current Calibration (%) ASIO Drive/ERROR ESBR SGLB Drive/Get Cal Field Current /2v127,-1.1000,1.1000;%1.4f ASIO Drive/ERROR ESBR SGLB Drive/Get Field Current /2v37,-200,200;Field Current is %3.2f%% ASIO Drive/ERROR ESBR ESTR CMTL 5 graphic info CMNT 4 -18,-18,1800,1368 CMTL 3 0 CMNT 24 20,0,72,45,3,1,FIELD DEMAND;Drive/Field Demand CMNT 24 20,0,144,45,2,2,FIELD CONTROL MODE;Drive/Field Control Mode CMNT 24 20,0,216,45,2,1,FIELD ENABLE;Drive/Field Enable CMNT 24 20,0,288,45,3,2,INTEGRAL GAIN;Drive/Field Loop I Gain CMNT 24 20,0,360,45,3,3,PROP GAIN;Drive/Field Loop P Gain CMNT 24 20,0,432,45,4,1,FIELD WEAKENING ENABLE;Drive/Field Weakening Enable CMNT 24 20,0,504,45,4,2,EMF LEAD;Drive/EMF Lead CMNT 24 20,0,576,45,4,3,EMF LAG;Drive/EMF Lag CMNT 24 20,0,648,45,4,4,EMF GAIN;Drive/EMF Gain CMNT 24 20,0,720,45,4,5,MAX ARMATURE VOLTS;Drive/Max Volts CMNT 24 20,0,792,45,4,6,MINIMUM FIELD CURRENT;Drive/Minimum Field Current CMNT 24 20,0,864,45,2,5,FIELD QUENCH MODE;Drive/Field Quench Mode CMNT 24 20,0,936,45,2,4,FIELD QUENCH DELAY;Drive/Field Quench Delay CMNT 24 20,0,1008,45,5,1,FIELD RATIO;Drive/Field Ratio Out|In CMNT 24 20,0,1080,45,2,3,CAL FIELD CURRENT;Drive/Cal Field Current ECMT CMTL 7 0 CMNT 22 -10,68,0,3,1,Drive/Get Field Demand;/w,-20000,20000,0.01,%.2f%% CMNT 22 -10,140,0,2,2,Drive/Get Field Control Mode;/t,Voltage,Current CMNT 22 -10,212,0,2,1,Drive/Get Field Enable;/t,Disabled,Enabled CMNT 22 -10,284,0,3,2,Drive/Get Field Loop I Gain;/w,-10000,10000,0.01,%.2f CMNT 22 -10,356,0,3,3,Drive/Get Field Loop P Gain;/w,-10000,10000,0.01,%.2f CMNT 22 -10,428,0,4,1,Drive/Get Field Weakening Enable;/t,Disabled,Enabled CMNT 22 -10,500,0,4,2,Drive/Get EMF Lead;/w,-5000,5000,0.01,%.2f CMNT 22 -10,572,0,4,3,Drive/Get EMF Lag;/w,-20000,20000,0.01,%.2f CMNT 22 -10,644,0,4,4,Drive/Get EMF Gain;/w,-10000,10000,0.01,%.2f CMNT 22 -10,716,0,4,5,Drive/Get Max Volts;/w,-10000,10000,0.01,%.2f%% CMNT 22 -10,788,0,4,6,Drive/Get Minimum Field Current;/w,-10000,10000,0.01,%.2f%% CMNT 22 -10,860,0,2,5,Drive/Get Field Quench Mode;/t,Quench,Standby CMNT 22 -10,932,0,2,4,Drive/Get Field Quench Delay;/w,0,6000,0.1,%.1fs CMNT 22 -10,1004,0,5,1,Drive/Get Field Ratio Out|In;/w,0,10000,0.01,%.2f%% CMNT 22 -10,1076,0,2,3,Drive/Get Cal Field Current;/w,0,11000,0.0001,%.4f CMNT 14 1792,68,1,0,1,Drive/Get Total Field Setpoint;/w,-20000,20000,0.01,%.2f%% CMNT 14 1792,1220,1,0,2,Drive/Get Field Current;/w,-20000,20000,0.01,%.2f%% ECMT CMNT 8 0,0,1782,1350 ECMT