STRE Prototype SGLB Misc/Class Reference CLAS 354272 Analog Output ESBR SORD 3 LITO 0 /t,Voltage,Current;Output type PORD 1 /t,Disabled,Enabled;Channel Status ESBR ESTR STRE SGLB Misc/Superclass Reference CLAS 354008 Object ESBR SGLB General/Initialize for internal class use only CMNT Expects: É ¥ inst/É MACR Output Setup LITO 3 É ¥ 3/inst/É PRIM S_tree/Entry to stack É ¥ status/type/inst/É ASIO Analog/ANLG_OP_TYPE É ¥ inst/É PRIM Heap/Store self É ¥ É EMAC ESBR SGLB Analog/Setpoint /3v34,-100,100,0,100;Output (0 - 100 %) ... CMNT Expects: É ¥ inst/data/É LITO 2 É ¥ 2/inst/data/É LITO 3 É ¥ 3/2/inst/data/É PRIM S_tree/Read É ¥ status/inst/data/É CMNT drop output if disabled BRFL É ¥ inst/data/É PRIM Stack/Xdrop É ¥ inst/É PRIM Heap/Store self É ¥ É BRTR PRIM Stack/Swap É ¥ data/inst/É PRIM Analog/SEND_ANLG_OUT É ¥ inst/É PRIM Heap/Store self É ¥ É ESBR SGLB Analog/Get Setpoint /2v6,-100,100;%3.2f%% CMNT Expects: É ¥ inst/route/É LITO 0 É ¥ 0/inst/route/É (output is channel 0) ASIO Analog/GET_ANLG_INPUT É ¥ data/inst/route/É PRIM Tags/Set literal CALL 354056 Respond withData ESBR SGLB Analog/Get Status /2t11,Disabled,Enabled LITO 2 CALL 354074 Method 3 Get ESBR SGLB Analog/Status /3t12,Disable,Enable;SelectÉ PRIM Stack/Swap É ¥ new status/inst/É LITO 2 É ¥ 2/new status/inst/É LITO 3 É ¥ 3/2/new status/inst/É PRIM S_tree/Replace É ¥ inst/É MACR Output Setup LITO 3 É ¥ 3/inst/É PRIM S_tree/Entry to stack É ¥ status/type/inst/É ASIO Analog/ANLG_OP_TYPE É ¥ inst/É PRIM Heap/Store self É ¥ É EMAC ESBR ESTR CMTL 5 graphic info CMNT 4 -18,-18,418,296 CMTL 3 0 CMNT 24 20,0,144,45,0,1,SETPOINT;Analog/Setpoint CMNT 24 20,0,216,45,3,2,STATUS;Analog/Status ECMT CMTL 7 0 CMNT 18 200,70,0,3,1,;/t,VOLTAGE,CURRENT CMNT 22 -10,136,1,0,1,Analog/Get Setpoint;/v,-100,100;%3.2f%% CMNT 22 -10,208,0,3,2,Analog/Get Status;/t,DIS,EN ECMT CMNT 8 0,0,400,280 ECMT