STRE Prototype SGLB Misc/Class Reference CLAS 354016 ESBR SGLB Drive/Get Total Field Setpoint LCON /*;Total Field Setpoint ESBR SGLB Drive/Get Field Control Mode LCON /*;Field Control Mode ESBR SGLB Drive/Get Field Enable LCON /*;Field Enable ESBR SGLB Drive/Get Field Loop I Gain LCON /*;Field Loop I Gain ESBR SGLB Drive/Get Field Loop P Gain LCON /*;Field Loop P Gain ESBR SGLB Drive/Get Field Weakening Enable LCON /*;Field Weakening Enable ESBR SGLB Drive/Get EMF Lead LCON /*;EMF Lead ESBR SGLB Drive/Get EMF Lag LCON /*;EMF Lag ESBR SGLB Drive/Get EMF Gain LCON /*;EMF Gain ESBR SGLB Drive/Get Max Volts LCON /*;Max Volts ESBR SGLB Drive/Get Minimum Field Current LCON /*;Minimum Field Current ESBR SGLB Drive/Get Field Quench Mode LCON /*;Field Quench Mode ESBR SGLB Drive/Get Field Quench Delay LCON /*;Field Quench Delay ESBR SGLB Drive/Get Field Ratio Out|In LCON /*;Field Ratio Out|In ESBR SGLB Drive/Get Cal Field Current LCON /*;Cal Field Current ESBR SGLB Drive/Get Field Weakening Range LCON /*;Field Weakening Range ESBR SGLB Drive/Get Field Current LCON /*;Field Current ESBR ESTR STRE SGLB Misc/Superclass Reference CLAS 354008 ESBR SGLB Drive/Get Total Field Setpoint /2v,-200,200;Total Field Setpoint is %3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Field Control Mode /3t,Voltage,Current;Choose Control Mode ASIO Drive/ERROR ESBR SGLB Drive/Get Field Control Mode /2t,Voltage Control,Current Control ASIO Drive/ERROR ESBR SGLB Drive/Field Enable /3t,Disable,Enable;Field Enable ASIO Drive/ERROR ESBR SGLB Drive/Get Field Enable /2t,Field is Disabled,Field is Enabled ASIO Drive/ERROR ESBR SGLB Drive/Field Loop I Gain /3v,-5,5,0,5;Enter Field Loop I Gain ASIO Drive/ERROR ESBR SGLB Drive/Get Field Loop I Gain /2v,-5,5;Field Loop I Gain is %3.2f ASIO Drive/ERROR ESBR SGLB Drive/Field Loop P Gain /3v,-5,5,0,5;Enter Field Loop P Gain ASIO Drive/ERROR ESBR SGLB Drive/Get Field Loop P Gain /2v,-5,5;Field Loop P Gain is %3.2f ASIO Drive/ERROR ESBR SGLB Drive/Field Weakening Enable /3t,Disable,Enable;Field Weakening ASIO Drive/ERROR ESBR SGLB Drive/Get Field Weakening Enable /2t,Disabled,Enabled ASIO Drive/ERROR ESBR SGLB Drive/EMF Lead /3v,-50,50,0.1,50;Enter EMF Lead ASIO Drive/ERROR ESBR SGLB Drive/Get EMF Lead /2v,-50,50;EMF Lead is %3.2f ASIO Drive/ERROR ESBR SGLB Drive/EMF Lag /3v,-100,100,1,100;Enter EMF Lag ASIO Drive/ERROR ESBR SGLB Drive/Get EMF Lag /2v,-100,100;EMF Lag is %3.2f ASIO Drive/ERROR ESBR SGLB Drive/EMF Gain /3v,-5,5,0,5;Enter EMF Gain ASIO Drive/ERROR ESBR SGLB Drive/Get EMF Gain /2v,-5,5;EMF Gain is %1.2f ASIO Drive/ERROR ESBR SGLB Drive/Max Volts /3v,-100,100,0,100;Enter Max Field Voltage ASIO Drive/ERROR ESBR SGLB Drive/Get Max Volts /2v,-100,100;Max Field Voltage is %3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Minimum Field Current /3v,-100,100,0,100;Enter Minimum Field Current ASIO Drive/ERROR ESBR SGLB Drive/Get Minimum Field Current /2v,-100,100;Minimum Field Current is %3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Field Quench Mode /3t,Quench,Standby;Enter Field Quench Mode ASIO Drive/ERROR ESBR SGLB Drive/Get Field Quench Mode /2t,Quench,Standby ASIO Drive/ERROR ESBR SGLB Drive/Field Quench Delay /3v,-250,250,0.1,250;Enter Field Quench Delay (secs) ASIO Drive/ERROR ESBR SGLB Drive/Get Field Quench Delay /2v,-250,250;Field Quench Delay is %3.1f seconds ASIO Drive/ERROR ESBR SGLB Drive/Field Ratio Out|In /3v,-100,100,0,100;Enter Ratio (%) ASIO Drive/ERROR ESBR SGLB Drive/Get Field Ratio Out|In /2v,-100,100;Field Ratio is %3.0f%% ASIO Drive/ERROR ESBR SGLB Drive/Cal Field Current /3v,-110,110,90,110;Enter Field Current Calibration (%) ASIO Drive/ERROR ESBR SGLB Drive/Get Cal Field Current /2v,-110,110;Field Current Calibration is %3.2f%% ASIO Drive/ERROR ESBR SGLB Drive/Field Weakening Range /3v,-10,10,0,10;Range (X.Y | 1.0) ASIO Drive/ERROR ESBR SGLB Drive/Get Field Weakening Range /2v,-10,10;Range is %2.1f : 1.0 ASIO Drive/ERROR ESBR SGLB Drive/Get Field Current /2v,-200,200;Field Current is %3.2f%% ASIO Drive/ERROR ESBR ESTR