RELEASE 3.6 VECTOR DRIVE 2.2 kW 380-460v ..MENU LEVEL ....DIAGNOSTICS [5 ] = 0 ......TOTAL SPD.DMD. [6 ] = 0.00 % h.....SPEED FB UNFIL [7 ] = 0.00 % ......SPEED FEEDBACK [11 ] = 0.00 % ......SPEED ERROR [8 ] = 0.00 % ......TORQUE DEMAND [9 ] = 0.00 % ......TORQUE FEEDBACK [10 ] = 0.00 % ......CURRENT FEEDBACK [78 ] = 0.00 % f.....TERMINAL VOLTS [480] = 0 VOLTS f.....DC LINK VOLTS [613] = 512 VOLTS h.....DC VOLTS UNFLT [684] = 514 VOLTS f.....TERM V INTEGRAL [623] = 100.00 % ......ACTUAL POS I LIM [13 ] = 100.00 % ......ACTUAL NEG I LIM [14 ] = -100.00 % ......INVERSE TIME O/P [15 ] = 200.00 % ......AT CURRENT LIMIT [16 ] = FALSE ......AT ZERO SPEED [17 ] = TRUE ......AT ZERO SETPOINT [18 ] = TRUE ......AT STANDSTILL [19 ] = TRUE ......STALL TRIP [20 ] = OK ......RAMPING [21 ] = FALSE ......DRIVE START [23 ] = FALSE ......DRIVE ENABLE [24 ] = FALSE ......OPERATING MODE [25 ] = STOPPED ......HEALTHY [27 ] = TRUE ......HEALTH OUTPUT [12 ] = TRUE ......READY [559] = FALSE ......RUN [28 ] = FALSE f.....CO-PRO PRESENT [150] = FALSE ......ANIN 1 (C3) [29 ] = 0.000 VOLTS ......ANIN 3 (F2) [31 ] = 0.002 VOLTS ......ANIN 4 (F3) [32 ] = 0.002 VOLTS ......ANIN 5 (F4) [33 ] = 0.000 VOLTS ......ANOUT 1 (C5) [34 ] = 0.000 VOLTS ......ANOUT 2 (F5) [35 ] = 0.000 VOLTS ......COAST STOP [26 ] = FALSE ......PROGRAM STOP [22 ] = FALSE ......DIGIN B6 JOG [37 ] = FALSE ......DIGIN B7 START [36 ] = FALSE ......DIGIN B8 ENABLE [38 ] = FALSE ......DIGIN 1 (E2) [39 ] = FALSE ......DIGIN 2 (E3) [40 ] = FALSE ......DIGIN 3 (E4) [41 ] = FALSE ......DIGIN 4 (E5) [521] = FALSE ......DIGOUT 1 (E6) [42 ] = FALSE ......DIGOUT 2 (E7) [43 ] = TRUE ......DIGOUT 3 (E8) [44 ] = FALSE ......RAISE/LOWER O/P [45 ] = 0.00 % ......SPT SUM O/P 1 [46 ] = -0.07 % ......SPT SUM O/P 2 [385] = 0.07 % ......SPT SUM O/P 3 [386] = 0.00 % ......RAMP OUTPUT [47 ] = 0.00 % ......PRESET O/P [110] = 0.00 % ......SPEED SETPOINT [48 ] = -0.02 % f.....SEQ RUN INPUT [49 ] = -0.02 % f.....SEQ OUTPUT [50 ] = 0.00 % ......ENCODER [51 ] = 0 RPM ....SETUP PARAMETERS ......RAMPS ........RAMP ACCEL TIME [54 ] = 2.9 SECS * ........RAMP DECEL TIME [55 ] = 1.6 SECS * f.......RAMP QUENCH [56 ] = FALSE ........RAMP HOLD [57 ] = FALSE <- [281] ........RAMP INPUT [58 ] = 0.00 % <- [345] ........% S-RAMP [59 ] = 0.00 % ........RAMPING THRESH. [60 ] = 1.00 % ........AUTO RESET [61 ] = TRUE ........EXTERNAL RESET [62 ] = FALSE ........RESET VALUE [63 ] = 0.00 % ........RAMPING [21 ] = FALSE ........RAMP OUTPUT [47 ] = -0.07 % ......OP-STATION ........SET UP ..........SETPOINT [507] = 0.0 % ..........LOCAL KEY ENABLE [632] = TRUE ........START UP VALUES ..........SETPOINT [503] = 0.0 % ..........REV DIRECTION [504] = FALSE f.........PROGRAM [505] = FALSE ..........LOCAL [506] = FALSE ........LOCAL RAMP ..........RAMP ACCEL TIME [511] = 10.0 SECS ..........RAMP DECEL TIME [512] = 10.0 SECS h.........RAMP QUENCH [513] = TRUE * h.........RAMP HOLD [514] = FALSE h.........RAMP INPUT [515] = 0.00 % ..........% S-RAMP [516] = 0.00 % h.........RAMPING THRESH. [517] = 1.00 % h.........AUTO RESET [518] = TRUE h.........EXTERNAL RESET [519] = TRUE * h.........RESET VALUE [520] = 0.00 % h.........RAMP OUTPUT [509] = 0.00 % ......AUX I/O ........AUX START [66 ] = TRUE ........START [70 ] = FALSE <- [450] ........AUX JOG [67 ] = TRUE ........JOG INPUT [71 ] = FALSE <- [451] ........AUX ENABLE [68 ] = TRUE ........ENABLE [72 ] = FALSE <- [452] ......JOG ........JOG SPEED 1 [75 ] = -30.00 % * ........JOG SPEED 2 [76 ] = -10.00 % ........MODE [80 ] = FALSE ........JOG ACCEL RATE [113] = 1.1 SECS * ........JOG DECEL RATE [114] = 0.2 SECS * ......RAISE/LOWER ........RESET VALUE [82 ] = 0.00 % ........RAMP RATE [83 ] = 60.0 SECS ........RAISE INPUT [85 ] = FALSE ........LOWER INPUT [86 ] = FALSE ........MIN VALUE [87 ] = -100.00 % ........MAX VALUE [88 ] = 100.00 % ........EXTERNAL RESET [89 ] = FALSE ........RAISE/LOWER O/P [45 ] = 0.00 % h.......RAISE/LOWER INIT [678] = 0.00 % h.....INVERSE TIME h.......AIMING POINT [116] = 105.00 % h.......DELAY [117] = 60.0 SECS h.......DOWN RATE [118] = 10.0 SECS h.......UP RATE [148] = 120.0 SECS ........INVERSE TIME O/P [15 ] = 200.00 % ......STOP RATES ........RUN STOP TIME [120] = 10.0 SECS ........RUN STOP LIMIT [121] = 60.0 SECS ........FAST STOP TIME [123] = 1.0 SECS ........FAST STOP LIMIT [124] = 60.0 SECS ........USE SYSTEM RAMP [125] = TRUE f.......PRE-START DELAY [122] = 0.500 SECS f.......READY DELAY [352] = 0.000 SECS ........CONTACTOR DELAY [112] = 0.5 SECS ........STOP ZERO SPEED [126] = 1.00 % ........PROG STOP I-LIM [622] = 150.00 % ........COAST STOP [26 ] = FALSE ........PROGRAM STOP [22 ] = FALSE ......ALARMS ........EXTERNAL TRIP [144] = FALSE h.......MOTOR TEMP [141] = 26.39 % h.......MOTOR TMP.TRIP [128] = 75.00 % h.......MOTOR TMP.RST. [309] = 50.00 % ........MOTR.TMP.INHIBIT [146] = FALSE h.......HEATSINK LEVEL [129] = 17.00 % f.......ACK ALARM [166] = TRUE ........STALL INHIBIT [143] = FALSE ........STALL TORQUE [136] = 95.00 % ........STALL SPEED [138] = 4.00 % ........STALL DELAY [137] = 10.00 ........STALL TRIP [20 ] = OK ........OVER SPD INHIBIT [145] = FALSE ........OVER SPEED LEVEL [139] = 120.00 % ........5703 RCV.INHIBIT [142] = FALSE h.......PWR LOSS CNTRL h.........ENABLE [639] = FALSE h.........TRIP THRESHOLD [640] = 90.00 % h.........TRIP LEVEL [642] = 0 VOLTS h.........RATE %/1.1mS [641] = 5.00 % h.........TIME LIMIT [643] = 10.000 SECS * f.......SPD.FBK.DELAY [687] = 10.000 SECS f.......SPD.FBK.THRESHD [688] = 10.00 % ........SPD.FBK.INHIBIT [689] = FALSE h.......HEALTH INHIBIT [219] = 0x0000 f.......OPERATING MODE [25 ] = STOPPED f.......DRIVE START [23 ] = FALSE f.......DRIVE ENABLE [24 ] = FALSE f.......READY [559] = FALSE f.......RUN [28 ] = FALSE f.......HEALTH STORE [203] = 0x0000 f.......HEALTH WORD [217] = 0x0000 f.......FIRST ALARM [218] = 0x0000 f.......HEALTHY [27 ] = TRUE f.......HEALTH OUTPUT [12 ] = TRUE ......CALIBRATION ........ENCODER LINES [131] = 2048 ........MAX SPEED RPM [130] = 1622 RPM * ........BASE FREQUENCY [448] = 120.0 Hz * ........MOTOR VOLTS [486] = 391 VOLTS * ........MOTOR RATING RMS [134] = 6.0 AMPS * ........NO.OF POLES [399] = 4 ........NAMEPLATE RPM [135] = 3410 RPM * ......TORQUE LOOP ........MAG CURRENT % [453] = 70.85 % * ........ROTOR TIME CONST [458] = 25.0 mSECS * ........1 / GAIN [149] = 70 ........TORQ.DMD.ISOLATE [596] = FALSE ........POS TORQUE LIMIT [157] = 150.00 % ........NEG TORQUE LIMIT [158] = -150.00 % ........MAIN TORQUE LIM. [159] = 100.00 % ........SYMETRIC TQ.LIM. [153] = TRUE ........AUX TORQUE DMD [599] = 0.00 % ........ACTUAL POS I LIM [13 ] = 100.00 % ........ACTUAL NEG I LIM [14 ] = -100.00 % ........CURRENT LIMIT [585] = 150.00 % ........CURRENT FEEDBACK [78 ] = 0.00 % ........AT CURRENT LIMIT [16 ] = FALSE f.......TERMINAL VOLTS [480] = 0 VOLTS f.......DC LINK VOLTS [613] = 520 VOLTS h.......DC VOLTS UNFLT [684] = 524 VOLTS ........TORQUE DEMAND [9 ] = 0.00 % ........TORQUE FEEDBACK [10 ] = 0.00 % ......SPEED LOOP ........SPD. PROP. GAIN [161] = 10.00 ........SPD. INT. TIME [162] = 100 mSECS f.......INT. DEFEAT [163] = FALSE ........ENCODER SIGN [164] = NEG f.......SPEED FBK FILTER [673] = 0.500 f.......SPEED DMD FILTER [662] = 0.750 f.......ADAPTIVE THRESH [674] = 0.50 % f.......ADAPTIVE P-GAIN [675] = 10.00 ........SPEED SETPOINTS ..........DIRECT SPT1 [171] = 0.00 % ..........DIRECT RATIO [172] = 0.1000 ..........DIRECT SPT. MAX [173] = 100.00 % ..........DIRECT SPT. MIN [174] = -100.00 % ..........DIRECT ENABLE [175] = FALSE ..........MAIN SPD.SPT. [176] = 0.00 % <- [346] ..........MAX SPEED [177] = 100.00 % ..........MIN SPEED [178] = -100.00 % ..........ZERO SPD HYST [132] = 0.10 % ..........ZERO SPEED LEVEL [252] = 0.50 % ..........AT ZERO SPEED [17 ] = TRUE ..........AT ZERO SETPOINT [18 ] = TRUE ..........AT STANDSTILL [19 ] = TRUE f.........SEQ RUN INPUT [49 ] = -0.02 % f.........SEQ OUTPUT [50 ] = 0.00 % f.......TEST MODE f.........ENABLE [647] = FALSE f.........SPEED SETPOINT 1 [648] = 5.00 % f.........SPEED SETPOINT 2 [649] = 10.00 % f.........PERIOD [650] = 1000 mSECS ........TOTAL SPD.DMD. [6 ] = 0.00 % h.......SPEED FB UNFIL [7 ] = 0.00 % ........SPEED FEEDBACK [11 ] = 0.00 % ........SPEED ERROR [8 ] = 0.00 % ........ENCODER [51 ] = 0 RPM ........SPEED SETPOINT [48 ] = 0.00 % ......AUTOTUNE ........AUTOTUNE FLAG [482] = FALSE ........MAG I AUTOTUNE [483] = FALSE * ........SET Tr < RTD SPD [484] = TRUE ........AUTOCAL MAX RPM [629] = 30000 RPM ......SETPOINT SUM 1 ........RATIO 0 [189] = 1.0000 ........RATIO 1 [190] = 1.0000 ........SIGN 0 [191] = POS ........SIGN 1 [192] = POS ........DIVIDER 0 [193] = 1.0000 ........DIVIDER 1 [194] = 1.0000 ........LIMIT [195] = 100.00 % ........INPUT 0 [196] = 0.00 % <- [251] ........INPUT 1 [197] = -0.02 % <- [259] ........INPUT 2 [198] = 0.00 % ........SPT SUM O/P 1 [46 ] = -0.10 % ......SETPOINT SUM 2 ........RATIO 1 [365] = 1.0000 ........RATIO 0 [364] = 1.0000 ........SIGN 1 [367] = NEG * ........SIGN 0 [366] = POS ........DIVIDER 1 [369] = 1.0000 ........DIVIDER 0 [368] = 1.0000 ........LIMIT [370] = 100.00 % ........INPUT 0 [371] = 0.00 % <- [305] ........INPUT 1 [372] = -0.10 % <- [308] ........INPUT 2 [373] = 0.00 % <- [111] ........SPT SUM O/P 2 [385] = 0.00 % ......SETPOINT SUM 3 ........RATIO 1 [376] = 1.0000 ........RATIO 0 [375] = 1.0000 ........SIGN 1 [378] = POS ........SIGN 0 [377] = POS ........DIVIDER 1 [380] = 1.0000 ........DIVIDER 0 [379] = 1.0000 ........LIMIT [381] = 100.00 % ........INPUT 0 [382] = 0.00 % ........INPUT 1 [383] = 0.00 % ........INPUT 2 [384] = 0.00 % ........SPT SUM O/P 3 [386] = 0.00 % f.....REF ENCODER f.......PHASE f.........OFFSET [447] = 0 f.........OFFSET SCALE [609] = 1 f.........OFFSET TRIM [670] = 0 f.........RESET [600] = FALSE f.........POS CALC ENABLE [337] = FALSE f.........TEST MODE f...........ENABLE [652] = FALSE f...........OFFSET 1 [653] = 500 f...........OFFSET 2 [654] = 1000 f...........PERIOD [655] = 1000 mSECS f.........MAX POSITION ERR [342] = 100.00 f.........FBK.SCALE A [498] = 10000 f.........FBK.SCALE B [499] = 10000 h.........REF ENCODER CNT [359] = 0 h.........FBK ENCODER CNT [77 ] = 0 f.........SATURATED [610] = FALSE f.........OVERFLOW [611] = FALSE f.........POSITION ERROR [338] = 0 f.......INCH f.........INCH ADVANCE [604] = FALSE f.........INCH RETARD [605] = FALSE f.........INCH RATE [606] = 10.0 f.......CALC.REF.POSTION f.........ENABLE [659] = FALSE f.........INPUT [660] = 0.00 % f.........OUTPUT [661] = 0 f.....PID f.......INPUT [545] = 0.00 % <- [556] f.......ENABLE [534] = TRUE f.......PROP.GAIN [549] = 1.0 f.......INT.TIME CONST. [539] = 5.00 SECS f.......INT.DEFEAT [538] = FALSE f.......DERIVATIVE TC [531] = 0.000 SECS f.......FILTER TC [535] = 0.100 SECS f.......POSITIVE LIMIT [547] = 100.00 % f.......NEGATIVE LIMIT [542] = -100.00 % f.......O/P SCALER(TRIM) [543] = 1.0000 f.......ERROR CALC f.........INPUT 1 [536] = 0.00 % f.........INPUT 2 [537] = 0.00 % f.........RATIO 1 [550] = 1.0000 f.........RATIO 2 [551] = 1.0000 f.........SIGN 1 [601] = POS f.........SIGN 2 [602] = POS f.........DIVIDER 1 [532] = 1.0000 f.........DIVIDER 2 [533] = 1.0000 f.........LIMIT [553] = 100.00 % f.........ERROR O/P [500] = 0.00 % f.......PROFILER f.........MODE [541] = 0 f.........MIN PROFILE GAIN [540] = 20.00 % f.........PROFILED GAIN [548] = 0.0 f.........PROFILE INPUT [554] = 0.00 % f.........PROFILE MININPUT [555] = 0.00 % f.......OUTPUT [546] = 0.00 % f.......CLAMPED [544] = TRUE ......PRESET ........SELECT 1 [92 ] = FALSE <- [285] ........SELECT 2 [93 ] = FALSE <- [289] ........SELECT 3 [94 ] = FALSE <- [525] ........INVERT O/P [109] = FALSE ........INPUT 1 [95 ] = 0.00 % ........INPUT 2 [96 ] = 25.00 % ........INPUT 3 [97 ] = 50.00 % ........INPUT 4 [98 ] = 100.00 % ........INPUT 5 [99 ] = 0.00 % ........INPUT 6 [100] = -25.00 % ........INPUT 7 [101] = -50.00 % ........INPUT 8 [102] = -100.00 % ........PRESET O/P [110] = 0.00 % f.....S-RAMP f.......INPUT [597] = 0.00 % f.......SYMMETRIC [667] = TRUE f.......ACCELERATION [106] = 10.00 f.......DECELERATION [666] = 10.00 f.......JERK 1 [107] = 10.00 f.......JERK 2 [663] = 10.00 f.......JERK 3 [664] = 10.00 f.......JERK 4 [665] = 10.00 f.......AUTO RESET [669] = TRUE f.......EXTERNAL RESET [104] = FALSE f.......RESET VALUE [105] = 0.00 % f.......QUENCH [108] = FALSE f.......AT SPEED [316] = FALSE f.......AT SPEED LEVEL [612] = 1.00 % h.......ACCEL O/P [253] = 0.00 h.......OVERSHOOT THRESH [254] = 5.00 % h.......ERROR THRESHOLD [668] = 0.50 % f.......OUTPUT [598] = 0.00 % f.....HOME f.......HOME [397] = FALSE f.......HOMING DISTANCE [396] = 2048 f.......1/ENCODER SCALE [398] = 4.00 f.......LINEAR O/P [388] = FALSE f.......HOME INPUT [394] = 0.00 % f.......HOME OUTPUT [395] = 0.00 % ....PASSWORD ......ENTER PASSWORD [200] = 0x0000 ......CHANGE PASSWORD [201] = 0x0000 ....ALARM STATUS ......HEALTH STORE [203] = 0x0000 ......HEALTH WORD [217] = 0x0000 ......FIRST ALARM [218] = 0x0000 h.....HEALTH INHIBIT [219] = 0x0000 ....MENUS ......FULL MENUS [205] = TRUE ......CONTRAST [220] = 253 * f.....MENU DELAY [206] = 3 * f.....DATA DELAY [207] = 50 ....SERIAL LINKS f.....P3 MODE [237] = EI BUSY * f.....P3 BAUD RATE [241] = 9600 f.....5703 SUPPORT f.......SETPT. RATIO [233] = 1.0000 f.......SETPT. SIGN [234] = NEG f.......SCALED INPUT [235] = 0.00 % f.......RAW INPUT [584] = 0.00 % f.......OUTPUT [236] = -0.02 % * ......DUMP MMI (TX) [238] = UP TO ACTION h.....MEMORY DUMP [221] = FALSE ......UDP XFER (TX) [240] = UP TO ACTION ......UDP XFER (RX) [239] = UP TO ACTION ......EI ASCII f.......GROUP ID (GID) [223] = 0 f.......UNIT ID (UID) [224] = 0 f.......OPTION ADDRESS [230] = 0 f.......OPTION VERSION [672] = 0.00 f.......ERROR REPORT [229] = 0x0000 f.....P3 TAG LIST f.......TAG 1 [212] = 7 f.......TAG 2 [213] = 0 f.......TAG 3 [214] = 0 f.......TAG 4 [215] = 0 f.......TAG 5 [216] = 0 f.......FULL TAG LIST [334] = FALSE ....SYSTEM ......SOFTWARE ........RELEASE [0 ] = 3.6 f.....CONFIGURE I/O f.......CONFIGURE ENABLE [245] = FALSE f.......ANALOG INPUTS f.........ANIN 1 (C3) f...........CALIBRATION [248] = 100.00 % f...........OFFSET [358] = 0.00 % f...........MAX VALUE [249] = 100.00 % f...........MIN VALUE [250] = -100.00 % f...........DESTINATION TAG [251] = 196 f...........SCALED INPUT [390] = 0.00 % f...........ANIN 1 (C3) [29 ] = 0.000 VOLTS f.........ANIN 3 (F2) f...........CALIBRATION [256] = 100.00 % f...........OFFSET [360] = 0.00 % f...........MAX VALUE [257] = 100.00 % f...........MIN VALUE [258] = -100.00 % f...........DESTINATION TAG [259] = 197 f...........SCALED INPUT [391] = 0.00 % f...........ANIN 3 (F2) [31 ] = -0.005 VOLTS f.........ANIN 4 (F3) f...........CALIBRATION [261] = 100.00 % f...........OFFSET [361] = 0.00 % f...........MAX VALUE [262] = 100.00 % f...........MIN VALUE [263] = -100.00 % f...........DESTINATION TAG [264] = 0 f...........SCALED INPUT [392] = 0.05 % f...........ANIN 4 (F3) [32 ] = 0.000 VOLTS f.........ANIN 5 (F4) f...........CALIBRATION [266] = 100.00 % f...........OFFSET [362] = 0.00 % f...........MAX VALUE [267] = 100.00 % f...........MIN VALUE [268] = -100.00 % f...........DESTINATION TAG [269] = 0 f...........SCALED INPUT [393] = 0.00 % f...........ANIN 5 (F4) [33 ] = 0.000 VOLTS h.........ANIN FILTER [671] = 0.800 f.......ANALOG OUTPUTS f.........ANOUT 1 (C5) f...........% TO GET 10V [272] = -100.01 % * f...........OFFSET [332] = 0.00 % f...........HARDWARE OFFSET [676] = 0.00 % f...........CALIBRATION [330] = 100.00 % f...........MODULUS [335] = FALSE f...........ANOUT 1 [354] = 0.00 % f...........SOURCE TAG [273] = 7 f...........ANOUT 1 (C5) [34 ] = 0.000 VOLTS f.........ANOUT 2 (F5) f...........% TO GET 10V [275] = 150.00 % f...........OFFSET [333] = 0.00 % f...........HARDWARE OFFSET [677] = 0.00 % f...........CALIBRATION [331] = 100.00 % f...........MODULUS [336] = FALSE f...........ANOUT 2 [355] = 0.00 % f...........SOURCE TAG [276] = 9 f...........ANOUT 2 (F5) [35 ] = 0.000 VOLTS f.......DIGITAL INPUTS f.........DIGIN 1 (E2) f...........VALUE FOR TRUE [279] = 0.01 % f...........VALUE FOR FALSE [280] = 0.00 % f...........OUTPUT [527] = 0.00 % f...........DESTINATION TAG [281] = 57 f...........DIGIN 1 (E2) [39 ] = FALSE f.........DIGIN 2 (E3) f...........VALUE FOR TRUE [283] = 0.01 % f...........VALUE FOR FALSE [284] = 0.00 % f...........OUTPUT [528] = 0.00 % f...........DESTINATION TAG [285] = 92 f...........DIGIN 2 (E3) [40 ] = FALSE f.........DIGIN 3 (E4) f...........VALUE FOR TRUE [287] = 0.01 % f...........VALUE FOR FALSE [288] = 0.00 % f...........OUTPUT [529] = 0.00 % f...........DESTINATION TAG [289] = 93 f...........DIGIN 3 (E4) [41 ] = FALSE f.........DIGIN 4 (E5) f...........VALUE FOR TRUE [523] = 0.01 % f...........VALUE FOR FALSE [524] = 0.00 % f...........OUTPUT [508] = 0.00 % f...........DESTINATION TAG [525] = 94 f...........DIGIN 4 (E5) [521] = FALSE f.........DIGIN B6 DEST [451] = 71 f.........DIGIN B6 JOG [37 ] = FALSE f.........DIGIN B7 DEST [450] = 70 f.........DIGIN B7 START [36 ] = FALSE f.........DIGIN B8 DEST [452] = 72 f.........DIGIN B8 ENABLE [38 ] = FALSE f.......DIGITAL OUTPUTS f.........DIGOUT 1 f...........THRESHOLD (>) [292] = 0.00 % f...........INPUT [324] = 0.01 % * f...........OFFSET [321] = 0.00 % f...........MODULUS [293] = FALSE f...........INVERT [327] = TRUE * f...........SOURCE TAG [294] = 17 f...........DIGOUT 1 (E6) [42 ] = FALSE f.........DIGOUT 2 f...........THRESHOLD (>) [296] = 0.00 % f...........INPUT [325] = 0.01 % * f...........OFFSET [322] = 0.00 % f...........MODULUS [297] = FALSE f...........INVERT [328] = FALSE f...........SOURCE TAG [298] = 12 f...........DIGOUT 2 (E7) [43 ] = TRUE f.........DIGOUT 3 f...........THRESHOLD (>) [300] = 0.00 % f...........INPUT [326] = 0.00 % f...........OFFSET [323] = 0.00 % f...........MODULUS [301] = TRUE f...........INVERT [329] = FALSE f...........SOURCE TAG [302] = 559 f...........DIGOUT 3 (E8) [44 ] = FALSE f.......CONFIGURE 5703 f.........SOURCE TAG [304] = 176 f.........DESTINATION TAG [305] = 371 f.......BLOCK DIAGRAM f.........RAISE/LOWER DEST [307] = 0 f.........RAMP O/P DEST [308] = 372 f.........PRESET DEST [111] = 373 f.........S-RAMP DEST [103] = 0 f.........HOME DEST [389] = 0 f.........SPT SUM1 OP DEST [345] = 58 f.........SPT SUM2 OP DEST [346] = 176 f.........SPT SUM3 OP DEST [347] = 0 f.........Pid O/P DEST [552] = 0 f.........Pid ERROR DEST [556] = 545 f.........POSITION DEST [341] = 0 f.........REF.SPEED DEST [656] = 0 f.......INTERNAL LINKS f.........LINK 1 SOURCE [180] = 0 f.........LINK 1 DEST [181] = 0 f.........LINK 2 SOURCE [182] = 0 f.........LINK 2 DEST [183] = 0 f.........LINK 3 SOURCE [184] = 0 f.........LINK 3 DEST [185] = 0 f.........LINK 4 SOURCE [186] = 0 f.........LINK 4 DEST [187] = 0 f.........LINK 5 SOURCE [560] = 0 f.........LINK 5 DEST [561] = 0 f.........LINK 6 SOURCE [562] = 0 f.........LINK 6 DEST [563] = 0 f.........LINK 7 SOURCE [564] = 0 f.........LINK 7 DEST [565] = 0 f.........LINK 8 SOURCE [566] = 0 f.........LINK 8 DEST [567] = 0 f.........LINK 9 SOURCE [568] = 0 f.........LINK 9 DEST [569] = 0 f.........LINK 10 SOURCE [570] = 0 f.........LINK 10 DEST [571] = 0 f.........LINK 11 SOURCE [572] = 0 f.........LINK 11 DEST [573] = 0 f.........LINK 12 SOURCE [574] = 0 f.........LINK 12 DEST [575] = 0 f.........LINK 13 SOURCE [576] = 0 f.........LINK 13 DEST [577] = 0 f.........LINK 14 SOURCE [578] = 0 f.........LINK 14 DEST [579] = 0 f.........LINK 15 SOURCE [580] = 0 f.........LINK 15 DEST [581] = 0 f.........LINK 16 SOURCE [582] = 0 f.........LINK 16 DEST [583] = 0 h.....RESERVED h.......ENG USE ONLY h.........Id Iq LOOPS h...........Id PROP GAIN [401] = 2 h...........Id INT GAIN [402] = 500 h...........MAX Id DEMAND [403] = 7500 h...........MIN Id DEMAND [404] = -2000 h...........MAX Id INTEGRAL [405] = 7500 h...........MIN Id INTEGRAL [406] = -2000 h...........Iq INT GAIN [407] = 10000 h...........MAX Iq INTEGRAL [408] = 4000 h...........MIN Iq INTEGRAL [409] = -4000 h...........MAX Id HI word [415] = 0 h...........MIN Id HI word [416] = -1 h.........MISCELLANEOUS h...........584S CHASSIS [169] = TRUE h...........BYPASS PASSWORD [69 ] = FALSE h...........DISABLE CO-PRO [154] = FALSE h...........BRAKE THRESHOLD [411] = 936 h...........MODN INDEX [412] = 9000 h...........AD POS THRESHOLD [413] = 6 h...........AD NEG THRESHOLD [414] = 6 h...........DRIVE STATUS [168] = FALSE h...........DRIVE RATING RMS [133] = 6.3 AMPS h...........MID VOLTS [151] = TRUE h...........CHASSIS TYPE [152] = 4 h...........RESET VEC VARS [167] = FALSE * h...........RESET EAT [155] = FALSE h...........MIN MMI CYCLE TM [313] = 200 h...........MAX MMI CYCLE TM [314] = 4000 h...........CYCLE TIME [315] = 8000 h...........TICK LENGTH [497] = 13.254 h...........SYS TIME [351] = 0x99DE h...........SPD.FBK. TC [319] = 0.010 SECS h...........TORQUE.FBK.TC [320] = 0.010 SECS h...........P3 TAG LIST TC [318] = 0.010 SECS h...........IFB ADJUST [495] = 115.0 % h...........TOTAL TRIP COUNT [624] = 0x0000 h...........SYSTEM RESET [64 ] = FALSE h...........UNDER V LEVEL [685] = 440 VOLTS h.........../UNDER VOLTS [686] = TRUE h.........TEST FUNCTIONS h...........SELECT FUNCTION [418] = 0 h...........SPEED PERIOD [419] = 1000 h...........SPEED AMPLITUDE [420] = 500 h...........SPEED OFFSET [421] = 0 h...........CURRENT PERIOD [422] = 40 h...........CURR AMPLITUDE [423] = 200 h...........CURRENT OFFSET [424] = 0 h...........MEAS SPD LOOP BW [634] = FALSE h...........NO OF AVERAGES [635] = 30000 h...........IMPLSE CNT LNGTH [636] = 30000 h...........IMPULSE HEIGHT [637] = 30000 h.........TRACE h...........TRACE MODE [426] = 1 h...........PRESET COUNT [427] = 0 h...........NO OF PASSES [428] = 1 h...........TRACE 16 ITEMS [429] = FALSE h...........TRACE ADDRESS 1 [430] = 0xD8FA * h...........TRACE ADDRESS 2 [431] = 0x0074 * h...........TRACE ADDRESS 3 [432] = 0x00B0 * h...........TRACE ADDRESS 4 [433] = 0x0072 * h...........TRACE ADDRESS 5 [434] = 0x00B6 * h...........TRACE ADDRESS 6 [435] = 0x00C0 * h...........TRACE ADDRESS 7 [436] = 0x00B2 * h...........TRACE ADDRESS 8 [437] = 0x00BE * h...........TRACE ADDRESS 9 [438] = 0x00CA * h...........TRACE ADDRESS 10 [439] = 0xF21A * h...........TRACE ADDRESS 11 [440] = 0x00C2 * h...........TRACE ADDRESS 12 [441] = 0xF21C * h...........TRACE ADDRESS 13 [442] = 0xF218 * h...........TRACE ADDRESS 14 [443] = 0x0092 * h...........TRACE ADDRESS 15 [444] = 0xD870 * h...........TRACE ADDRESS 16 [445] = 0x00BC * h.........FIELD WK VARS h...........MAG I SCALE 0 [454] = 100.0 % h...........MAG I SCALE 1 [455] = 77.0 % h...........MAG I SCALE 2 [456] = 63.0 % h...........MAG I SCALE 3 [457] = 50.0 % h...........MAG I SCALE 4 [586] = 40.0 % h...........MAG I SCALE 5 [459] = 35.0 % h...........MAG I SCALE 6 [460] = 30.0 % h...........MAG I SCALE 7 [461] = 25.0 % h...........MAG I SCALE 8 [462] = 20.0 % h...........MAG I SCALE 9 [630] = 11.1 % h...........TR SCALE 0 [587] = 100.0 % h...........TR SCALE 1 [588] = 100.0 % h...........TR SCALE 2 [589] = 100.0 % h...........TR SCALE 3 [590] = 100.0 % h...........TR SCALE 4 [591] = 100.0 % h...........TR SCALE 5 [592] = 100.0 % h...........TR SCALE 6 [593] = 100.0 % h...........TR SCALE 7 [594] = 100.0 % h...........TR SCALE 8 [595] = 100.0 % h...........TR SCALE 9 [631] = 100.0 % h.........AUTOTUNE MISC h...........kimr_int [487] = 1000 h...........AUTO RAMP INCRMT [488] = 2 h...........LINK V FILT GAIN [489] = 500 h...........TERM V FILT GAIN [490] = 500 h...........TERM V FLTGN DSP [491] = 50 h...........AUTOCAL MAX RPM [492] = 0 RPM h...........LOAD FACTOR @BS [493] = 95.0 % h...........LOAD FACTOR @2BS [494] = 90.0 % h...........MIN LINK V RATIO [628] = 85.00 % h.........TERM V CONTROL h...........% LOAD @BASE SPD [614] = 5.00 % h...........TVolts INT RANGE [615] = 50.00 % h...........SPD @ TV INT =0 [616] = 50.00 % h...........iq @TV INTGN=MIN [617] = 100.0 % h...........iq @TV INTGN=MAX [618] = 200.0 % h...........LOOP RESPNSE=nTr [619] = 20 h...........FAST RESPONSE % [620] = 102.50 % h...........TERM V INTEGRAL [623] = 100.00 % h.........DIAGNOSTICS RESD h...........SLIP FREQUENCY [625] = 0.00 Hz h...........RUN SLIP F DIAG [627] = FALSE h.....PERSISTENT DATA h......./WRITE [682] = FALSE h.......TAG No 1 [679] = 0 h.......TAG No 2 [680] = 0 h.......COUNT [681] = 0 f.....PEEK f.......PEEK TAG [340] = 7 f.......PEEK SCALE [350] = 100.00 % h.......PEEK DATA [349] = [0xC000] = 0000 ....PARAMETER SAVE [208] = UP TO ACTION ......SAVE (U/D) ....CONFIGURE DRIVE ......ENCODER LINES [131] = 2048 ......MAX SPEED RPM [130] = 1622 RPM * ......BASE FREQUENCY [448] = 120.0 Hz * ......MOTOR VOLTS [486] = 391 VOLTS * ......MOTOR RATING RMS [134] = 6.0 AMPS * ......NO.OF POLES [399] = 4 ......NAMEPLATE RPM [135] = 3410 RPM * ......MAG CURRENT % [453] = 70.85 % * ......ROTOR TIME CONST [458] = 25.0 mSECS * ......ENCODER SIGN [164] = NEG ......MAIN TORQUE LIM. [159] = 100.00 % ......AUTOTUNE FLAG [482] = FALSE ......SPD. PROP. GAIN [161] = 10.00 ......SPD. INT. TIME [162] = 100 mSECS NOTES: * Parameter is not at factory default. f Menu is only visible with FULL MENU = TRUE. h Menu is hidden and is for engineering use only.